15 research outputs found

    SPHINCS+^+ post-quantum digital signature scheme with Streebog hash function

    Full text link
    Many commonly used public key cryptosystems will become insecure once a scalable quantum computer is built. New cryptographic schemes that can guarantee protection against attacks with quantum computers, so-called post-quantum algorithms, have emerged in recent decades. One of the most promising candidates for a post-quantum signature scheme is SPHINCS+^+, which is based on cryptographic hash functions. In this contribution, we analyze the use of the new Russian standardized hash function, known as Streebog, for the implementation of the SPHINCS+^+ signature scheme. We provide a performance comparison with SHA-256-based instantiation and give benchmarks for various sets of parameters.Comment: 5 pages, 2 figures, 3 table

    Quantum-secured blockchain

    Full text link
    Blockchain is a distributed database which is cryptographically protected against malicious modifications. While promising for a wide range of applications, current blockchain platforms rely on digital signatures, which are vulnerable to attacks by means of quantum computers. The same, albeit to a lesser extent, applies to cryptographic hash functions that are used in preparing new blocks, so parties with access to quantum computation would have unfair advantage in procuring mining rewards. Here we propose a possible solution to the quantum era blockchain challenge and report an experimental realization of a quantum-safe blockchain platform that utilizes quantum key distribution across an urban fiber network for information-theoretically secure authentication. These results address important questions about realizability and scalability of quantum-safe blockchains for commercial and governmental applications.Comment: 7 pages, 2 figures; published versio

    Метод ИК-фотометрии для измерения концентрации глюкозы в растворе для перитонеального диализа

    Get PDF
    Introduction. The transition of glucose into the blood during automated peritoneal dialysis with regeneration of the dialysis fluid leads to a decreased removal of excess fluid from the body and corresponding violations of the water-salt balance.Aim. To consider a system for automatically maintaining the concentration of glucose in the dialysate solution, which provides effective ultrafiltration, as well as to propose a non-contact photometric feedback sensor.Materials and methods. The sensor is an optical system of an IR laser diode with a power of 30 mW and a wavelength of 1600 nm, a photodiode and a quartz tube, through which the test solution circulates. The sensor measures the attenuation of the radiation passing through the solution in a pulsed mode and calculates the glucose concentration. The selected combination of digital filters provides compensation for the noise of the optical system. Experimental studies of the efficiency of the sensor were carried out on peritoneal dialysis solutions with various concentrations of urea, creatinine, uric acid and glucose. At the beginning of the experiments, the sensor was calibrated in a pure solution.Results. It was shown that the developed sensor makes it possible to measure the concentration of glucose in a solution for peritoneal dialysis in the range of 42…220 mmol / l with a relative error of about 15%. The time of one measurement is about 1 minute, which makes it possible to obtain up-to-date information on the current concentration of the solution.Conclusion. This combination of characteristics will allow the sensor to be used in artificial kidney wearable devices for assessing the glucose content in the solution, calculating the time to change the solution and as a feedback sensor in a system for maintaining the concentration of the osmotic agent.Введение. Переход глюкозы в кровь при перитонеальном диализе с регенерацией диализирующего раствора приводит к снижению скорости удаления излишков жидкости из организма и соответствующим нарушениям водно-солевого баланса.Цель работы. Рассмотрена система автоматического поддержания концентрации глюкозы в диализирующем растворе, обеспечивающая эффективную ультрафильтрацию, а также предложен бесконтактный фотометрический датчик обратной связи.Материалы и методы. Датчик представляет собой оптическую пару из лазерного ИК-диода мощностью 30 мВт с длиной волны 1600 нм, фотодиода и кварцевой трубки, через которую осуществляется циркуляция исследуемого раствора. Датчик измеряет ослабление проходящего через раствор импульсного ИК-излучения, на основании которого рассчитывается концентрация глюкозы. Подобранная комбинация цифровых фильтров обеспечивает компенсацию шумов оптической пары. Экспериментальные исследования эффективности датчика проводились на растворах для перитонеального диализа с различными концентрациями мочевины, креатинина, мочевой кислоты и глюкозы. В начале экспериментов датчик калибровался на чистом растворе.Результаты. В результате экспериментов показано, что разработанный датчик позволяет измерять концентрацию глюкозы в растворе для перитонеального диализа в диапазоне 42…220 ммоль/л с относительной погрешностью около 15 %. Время одного измерения составляет примерно 1 мин, что позволяет получать актуальную информацию о текущей концентрации раствора.Заключение. Указанное сочетание характеристик позволит использовать датчик в носимых аппаратах "искусственная почка" для оценки содержания глюкозы в растворе, расчета времени замены раствора и в качестве датчика обратной связи для системы поддержания концентрации осмотического агента

    колективна монографія

    Get PDF
    Кримінальний процесуальний кодекс 2012 року: ідеологія та практика правозастосування: колективна монографія / за заг. ред. Ю. П. Аленіна ; відпов. за вип. І. В. Гловюк. - Одеса : Видавничий дім «Гельветика», 2018. - 1148 с
    corecore